Shenzhen Yehai Sci. & Tech. Deve. Co., Ltd.
Products
Contact Us
  • Contact Person : Ms. Chow Tracy
  • Company Name : Shenzhen Yehai Sci. & Tech. Deve. Co., Ltd.
  • Tel : 86-755-26509606-8803
  • Fax : 86-755-26502620
  • Address : Guangdong,Shenzhen,Room No.216,Third Floor,Jin Huiqiu Building,Langshan No.2Road,NorthArea,Science&TechnologyPark,Nanshan District,Shenzhen,China
  • Country/Region : China
  • Zip : 518057

8 TC,2/3/4 wires, accuracy 0.025%,Multifunction Process Calibrator-YHS726+free custom logo

8 TC,2/3/4 wires, accuracy 0.025%,Multifunction Process Calibrator-YHS726+free custom logo
Product Detailed
Related Categories:Other Electrical Instruments
Multifunction process calibrator YHS 726 1)Loop Power Voltage: 24V 2)Maximum Current: 24 mA, 3)A split-screen display

Multifunction Process Calibrator-YHS726

 Measure Accuracy:

Function

Measure Singal

Measure  Accuracy

Output

 

 

DC Voltage

0.000—30.000 V

0.02%+3 counts  (The upper display)

0.000—24.000 V

0.02%+ 3 counts (The lower display)

0.000—90.000 mV

0.01%+ 10 counts

-10.000 —80.000mV 0.01 % + 10 counts (use the thermocouple jack )

DC Current

0.000—24.000 mA

0.02%+ 4 counts(The upper display)

0.000—24.000 mA

0.02%+ 4 counts(The lower display)

Resistance

0.00— 400.00Ω

0.1Ω (4 wire), 0.15Ω (2 wire and 3 wire)

400.0—4000.0Ω

0.5Ω (4 wire), 1Ω (2 wire and 3 wire)

Frequency

0.010—20.000 kHz

±4Hz

0.001—39.999.0Hz

±0.01Hz

40.00 —99.99 Hz

±0.05Hz

100.0 —500.0 Hz

±0.5Hz

Pressure

Depends on the pressure module

Depends on the pressure module

 Output Accuracy:

Output

Range

    Accuracy

DC Voltage

0.000— 20.000 V

0.02%+3 counts

0.000—90.000 m V

0.01%+10 counts

-10.000 mV— 80.000 mV   0.01 % + 10 counts (use the thermocouple jack )

DC Current

0.000—24.000 mA

0.02%+ 4 counts

 

 

 

Resistance

5.00 — 400.00 Ω

0.15 Ω (Excitation current 0.15 to 0.5 mA), 0.1Ω (Excitation current 0.5 to 2 mA)

400.0 —4000.0 Ω

0.5Ω(Excitation current 0.05 to 0.8 mA)

Frequency

0.040—2.000 kHz

±2Hz

2.000—4.000 kHz

±8Hz

4.000—8.000 kHz

±32Hz

8.000—10.000KHz

±50Hz

Output Hz 

0.030—99.999Hz

±0.005Hz

Pressure

Depends on the pressure module

Depends on the pressure module

Loop Power Voltage: 24V

Accuracy: 10%Maximum Current: 24 mA, Short-circuit protection

the following characteristics:

 1,A split-screen display. 

 2,A thermocouple (TC) input/output terminal with cold junction temperature compensation,ambient temperature can be set and calibrate within the menu function.

 3,Each parameters can manual and automatic stepping and ramping output, signal output 

 4,In the configuration menu can be set manually : 

 5,Have calendar clock function,it can be calibrated in configuration menu.

 6,It can be store 8 sets of measurement and output data and call the showing at any time,all the settings and the functions of the last operation be auto-stored  after power off.

 7,The Calibrator and pressure module is hot-plugging, not need to turn off power, adaptive communications, abundant optional fitting.(Pressure module,Pressure pump,Adapter)

 8,High capacity rechargeable battery pack, can display chinese characters,digital key to input personalized , make the operation more simple.

 

Our Company guarantee:

 1. Free custom logo ;

2. 100% tested before shipping;

3. In 24Hours Delivery

8 TC,2/3/4 wires, accuracy 0.025%,Multifunction Process Calibrator-YHS726+free custom logo



Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.