Digital Multimter Loop Process Calibrator Similar to FLUKE 705

Digital Multimter Loop Process Calibrator Similar to FLUKE 705
Product Detailed
Related Categories:Multimeters
1.Process Calibrator. 2.Rechargeable Battery. 3.Current Voltage Calibrator. 4.Loop Power Output 5.Similar to FLUKE 705.

Multifunction Digital Loop Process Calibrator Similar to FLUIE 705 :

• LCD Max display  19999 with font height 22mm.• Over range displays “1”.• Power output 24V DC serving as the working power of 2-wire instrument.• 0-10V, 0-20mV, 0-100mV, 0-20mA and 0-22mA DC signal output serving as the input and output signal of type II and type III instruments and can simulate various of type II and type III instruments in field verification.• 200V, 20V, 200mV, 100mA and 20mA DC signal measurement•  working under condition of 24V power, output DC signal and measuring function simultaneously.• Quadruple half digits LCD display with the rotary switch, display the output value, measured value and unit

• Power:  Rechargeable battery,     charger• Operating Temperature :   -10ºC ~ 55ºC • Storage Temperature:    -40ºC ~ 60ºC • Humidity (Without Condensation):    0~90% (0ºC ~35ºC); 0~ 70% (35ºC~ 55ºC) • Temperature Coefficient :   -10ºC ~ 18ºC, 28ºC ~ 55ºC, ±.005% of range per ºC• Dimension: 195 * 92 * 55 mm• Weight: 400g 

-------------------------------------------------------------

Technical Specification:

1. Measurement Function Technical Specification:

DCV Measuring:

Range

Accuracy

Resolution

200V

± (0.1% +3 figures)

10mV

20V

± (0.1% +3 figures)

1mV

200mV

± (0.1%+3 figures)

10μV

DCA Measuring:

Range

Accuracy

Resolution

22mA

± (0.05% +3 figures)

10μV

20mA

± (0.05% +3 figures)

1μV

2. Signal Output Funtion:

DC voltage signal

Range

Accuracy

Resolution

10V

± (0.05% +3figures)

1mV

100mV

± (0.05% +3 figures)

10μV

20mV

± (0.05% +3 figures)

1μV

DC current signal

Range

Accuracy

Resolution

22mA

± (0.05% +3 figures)

10μV

20mA

± (0.05% +3 figures)

1μV

 3. Loop Power Supply:  24V

 ------------------------------------------------------

   

OR

Manufactory  Tour:

------------------------------------------------------------------

 Accessories:

       •  Test Leads

       •   Rechargeable batteries

       •  Charger

       •  Operational manual

-------------------------------------------------------------------

  Warranty:     one  year

 ------------------------------------------------------------------

-----------------------------------------------

   Contact:      Ms.  Elinor

   Mobile:         86-13699890579

   Skype:         elinor201012

    QQ:              761600474

----------------------------------------------

Digital Multimter Loop Process Calibrator Similar to FLUKE 705